Guides›Turnover and filtration rate

Circulation planning guide

Pool turnover period and filtration rate

These two inputs sound similar but answer different questions. Turnover period determines circulation flow; filtration rate determines the filter area needed for that flow.

What is turnover period?

Turnover period is the planning time required to circulate a volume equal to the pool water volume through the circulation system. It does not mean every water molecule passes through the filter exactly once.

Required circulation flow = pool volume ÷ turnover period

For the same pool volume, a shorter turnover period produces a higher required flow. Application, bathing load, treatment method and local rules influence the selected period.

What is filtration rate?

For a media filter, filtration rate is the flow passing through each square metre of effective filter area. It is commonly expressed in metres per hour.

Required filter area = circulation flow ÷ filtration rate

A lower filtration rate requires more filter area for the same circulation flow. The correct rate depends on the pool application, media, water-quality objective and product data.

Why the pool application matters

A private pool and a public or children’s pool can have very different operating conditions. The Bilanda calculator supplies application-based starting points so a customer is not left to invent a value. They remain editable because local codes or project requirements may call for something different.

  • Private pools commonly allow a longer turnover period and higher preliminary filtration rate.
  • Hotel and club pools generally require a more conservative starting point.
  • Public, competition and children’s pools may require shorter turnover or lower filtration rates.
  • Spa pools have small volume but can require rapid turnover because of concentrated bathing load.

A worked relationship

If a 375 m³ pool uses a 6-hour turnover period, the required circulation flow is 62.5 m³/h. At a preliminary filtration rate of 25 m/h, the required effective filter area is 2.50 m².

375 m³ ÷ 6 h = 62.5 m³/h
62.5 m³/h ÷ 25 m/h = 2.50 m²

Do not select the pump from flow alone

The calculated flow is a duty point, not a complete pump selection. Pipe length, fittings, elevation, equipment pressure loss, dirty-filter condition and the pump curve determine the required head and actual operating point.

Use the recommendations as starting points. Confirm the final turnover period and filtration rate against applicable local requirements and the selected equipment data before purchase.

Continue reading